Renesas Electronics /R7FA2E2A7 /I3C /IBINCTL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as IBINCTL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)NRHJCTL 0 (0)NRMRCTL 0 (0)NRSIRCTL

NRSIRCTL=0, NRHJCTL=0, NRMRCTL=0

Description

IBI Notify Control Register

Fields

NRHJCTL

Notify Rejected Hot-Join Control

0 (0): Do not pass rejected IBI Status to IBI Queue, if the incoming HotJoin request is NACKed and is autodisabled based on field HJACKCTL of BCTL.

1 (1): Pass rejected IBI Status to the IBI Queue, if the incoming Hot Join request is NACKed and is autodisabled based on field HJACKCTL of BCTL.

NRMRCTL

Notify Rejected Master Request Control

0 (0): Do not pass rejected IBI Status to IBI Queue/Ring, if the incoming Master Request is NACKed and is auto-disabled based on DVMRRJ field in relevant DAT entry.

1 (1): Pass rejected IBI Status to the IBI Queue, if the incoming Master Request is NACKed and is autodisabled based on DVMRRJ field in relevant DAT entry.

NRSIRCTL

Notify Rejected Slave Interrupt Request Control

0 (0): Do not pass rejected IBI Status to the IBI Queue/Rings, if the incoming SIR is NACKed and is auto-disabled based on DVSIRRJ field in relevant DAT entry.

1 (1): Pass rejected IBI Status to the IBI Queue/Rings, if the incoming SIR is NACKed and is auto-disabled based on DVSIRRJ field in relevant DAT entry.

Links

() ()